Simplify compliance testing and ensure success with our dependable, user-friendly combustion emissions analyzer
  • Combination of infrared measurement technology and electrochemical sensors
  • Automatic measuring program with data recording
  • Automatic zero-point measurement for long-term measurements

NOVAplus EMISSION  -  ANALYZER SET INCLUDING - O2 / CO / NO / NO2 and CO2*1QTYPart No.Unit Price
  • NOVA plus # 94010US PLUS - BASIC RCU # 63860
  • and industrial probe # 63981 with 9' sampling line and 12" exchangeable probe tube # 55583
  • and CO measurement # 63988 (0…4,000ppm / 20,000ppm)
  • and NO measurement # 63937 (0…1,000ppm / 5,000ppm)
  • and NO2 measurement # 64111 (0…200ppm / 1,000ppm) NO and NO2 needed for true NOx
  • CO protection # 64013 and MRU4win PC software # 10539
  • Peltier gas cooler # 63866
0947010-02$9,465.00
NOVAplus EMISSION - ANALYZER SET INCLUDING O2 / CO / NO / NO2 / SO2 / CO2*1QTYPart No.Unit Price
  • NOVA plus # 94010US PLUS - BASIC RCU # 63860
  • and industrial probe # 63981 with 9' sampling line and 12" exchangeable probe tube # 55583
  • and CO measurement # 63988 (0…4,000ppm / 20,000ppm)
  • and NO measurement # 63937 (0…1,000ppm / 5,000ppm)
  • and NO2 measurement # 64111 (0…200ppm / 1,000ppm) NO and NO2 needed for true NOx
  • and SO2 measurement # 63990 (0…2,000ppm / 5,000ppm)
  • CO protection # 64013 and MRU4win PC software # 10539
  • Peltier gas cooler # 63866
0947010-04$10,446.00

SELECT

Product total
Options total
Grand total
NOVA plus EMI RCU
NOVA plus EMI Probes 001
NOVA plus EMI Probes 002

NOVA Plus – Portable Emission Analyzer

$9,465.00

NOVA plus EMI RCU
NOVA plus EMI Probes 001
NOVA plus EMI Probes 002
Simplify compliance testing and ensure success with our dependable, user-friendly combustion emissions analyzer
  • Combination of infrared measurement technology and electrochemical sensors
  • Automatic measuring program with data recording
  • Automatic zero-point measurement for long-term measurements

NOVAplus EMISSION  -  ANALYZER SET INCLUDING - O2 / CO / NO / NO2 and CO2*1QTYPart No.Unit Price
  • NOVA plus # 94010US PLUS - BASIC RCU # 63860
  • and industrial probe # 63981 with 9' sampling line and 12" exchangeable probe tube # 55583
  • and CO measurement # 63988 (0…4,000ppm / 20,000ppm)
  • and NO measurement # 63937 (0…1,000ppm / 5,000ppm)
  • and NO2 measurement # 64111 (0…200ppm / 1,000ppm) NO and NO2 needed for true NOx
  • CO protection # 64013 and MRU4win PC software # 10539
  • Peltier gas cooler # 63866
0947010-02$9,465.00
NOVAplus EMISSION - ANALYZER SET INCLUDING O2 / CO / NO / NO2 / SO2 / CO2*1QTYPart No.Unit Price
  • NOVA plus # 94010US PLUS - BASIC RCU # 63860
  • and industrial probe # 63981 with 9' sampling line and 12" exchangeable probe tube # 55583
  • and CO measurement # 63988 (0…4,000ppm / 20,000ppm)
  • and NO measurement # 63937 (0…1,000ppm / 5,000ppm)
  • and NO2 measurement # 64111 (0…200ppm / 1,000ppm) NO and NO2 needed for true NOx
  • and SO2 measurement # 63990 (0…2,000ppm / 5,000ppm)
  • CO protection # 64013 and MRU4win PC software # 10539
  • Peltier gas cooler # 63866
0947010-04$10,446.00

SELECT

Product total
Options total
Grand total

Description

Features:

  • Industrial combustion and emissions tuning, trouble-shooting or compliance reporting
  • Simultaneous measurement up to 8 gases
  • Automatic calculations and data logging
  • Easy operation via intuitive, wireless Remote Control Unit
  • Rugged design for extreme field conditions
  • Accuracy and reliability

Benefits:

  • Make your combustion process more cost-effective.
  • Get the data to show your organization cares about the environment.

Applications:

Cement Industry, Gas Turbines, Compressor Stations, Glass Industry, Installers / Boiler Manufacturers, Power Plants, Refineries / Petrochem, Universities / Laboratory

Built to do more…

Base unit:

  • O2, CO, CO2, NO, NO2, CO-high, CO-very high, Stack temperature up to 2000°F, and Draft pressure to ±40”wc
  • Emission calculations of mass flow, calculated or True NOx plus O2 referencing to user defined values
  • Combustion calculations of CO2, CO/CO2 ratio, Excess air, Air ratio, Dewpoint, Efficiency, and Heat Losses
  • Large condensate separator with PTFE coated filter
  • High energy Li-Ion battery provides up to 20 hours of operation
  • Built-in speed printer easy paper loading for quick on-site documentation
  • Compact and rugged transport case

Options:

  • Gas conditioning via high efficiency Peltier gas cooler
  • CO protection with fresh air pump and cut-off valve
  • Internal flow monitoring
  • Auto zeroing

Basic Remote Control Unit:

  • Bluetooth communication with Base Unit
  • Large, color graphic display with ZOOM functions
  • Simple, intuitive operation with customizable screens
  • Durable, dirt resistant keypad
  • 16,000 measurement internal data storage
  • SD card reader for additional storage and easy data handling
  • High energy Li-Ion battery provides up to 30 hours of operation
  • Wireless battery charging via Base Unit cradle
  • USB and Bluetooth interface

Additional features of the Comfort RCU:

  • Integrated manometer for differential pressure and flow
  • Two (2) thermocouple inputs for differential temperature
  • Auxiliary (AUX) for optional humidity or gas leak probe

Software options:

  • MRU Online View Software for real-time monitoring and reporting
  • MRU 4 U Application for iOS and Android SMART devices

Warranty – 3 Years on the analyzer and accessories

(2 years on O2 sensor – 1 year on other gas sensors)

Measured componentsMeasuring RangesResolutionAccuracy
O2 Oxygen0 … 21 Vol % OPTIONAL (25%)0.1 %± 0.2 Vol-% abs.
CO Carbon monoxide0 … 4,000 ppm / overload 10,000ppm *11 ppm± 10 ppm or 5 % reading < 4,000 ppm / 10 % reading > 4,000 ppm
CO Carbon monoxide (low)0 … 300 ppm *20.1 ppm± 2.0 ppm or 5 % reading
CO Carbon monoxide (high)0 … 4.000 ppm / overload 10.000 ppm *11 ppm± 100 ppm or 5 % reading < 4.000 / 10 % reading > 4.000 ppm
NO Nitric oxide0 … 1,000 ppm / overload 5,000ppm *11 ppm± 5.0 ppm or 5 % reading < 1,000 ppm / 10 % reading > 1,000 ppm
NO Nitric oxide (low)0 … 300 ppm *20.1 ppm± 2.0 ppm or 5 % reading
NO2 Nitrogen dioxide0 … 200 ppm / overload 1,000ppm *11 ppm± 5 ppm or 5 % reading < 200 ppm / 10 % reading > 200 ppm
NO2 Nitrogen dioxide (low)0 … 300 *20.1 ppm± 2.0 ppm or 5 % reading
SO2 Sulfur dioxide0 … 2,000 ppm / overload 5,000ppm *11 ppm± 10 ppm or 5 % reading < 2,000 ppm / 10 % reading > 2,000 ppm
SO2 Sulfur dioxide (low)0 … 300 *20.1 ppm± 2.0 ppm or 5 % reading
H2S Hydrogen Sulfide0 … 500 ppm / Overload 2000 ppm *11 ppm± 5 ppm or 5 % reading < 500 ppm / 10 % reading > 500 ppm
*1 – overload ranges are recommended only for short time measurements
*2 – are not separate sensors; selected sensors are used with special calibration

 

1-gas NDIR benchMeasuring rangeResolutionAccuracy
CO2Carbon dioxide0 … 40 Vol %0.1 %± 0.3 % or 5 % of the measured value**

 

2-gas NDIR benchMeasuring rangeResolutionAccuracy
CO2Carbon dioxide0 … 40 Vol %0.1 %± 0.5 % or 5 % of the measured value
CH4Methane100 … 40,000 ppm10 ppm± 400 ppm or 5% reading

 

3-gas NDIR benchMeasuring rangeResolutionAccuracy
COCarbon monoxide0 … 2,000 ppm up to 10 %0.1 %± 0.03 % or 3 % of the measured value**
CO2Carbon dioxide0 … up to max 50 %0.1 %± 0.5 % or 3 % of the measured value**
CH4Methane    or0 … 2,000 ppm up to 4 %0.1 %± 0.03 % or 3 % of the measured value**
C3H8Propane0 … 2,000 ppm up to 20,000 ppm0.1 %± 30 ppm % or 3 % of the measured value**

 

Other measured componentsMeasuring RangesAccuracy
Stack / Flue gas temperature

32 … 1,472°F (0 … 800°C) with stainless steel

32 … 2,012°F (0 … 1100°C) with Inconel

± 4°F … < 392°F / 1 % reading > 392°F

± 4°F … < 392°F / 1 % reading > 392°F

Primary air / Ambient air temperature32 … 212°F    (0 … 100 °C)± 2°F
Differential temperature

Up to 2,012°F (0 … 1100°C)

(with suitable material of sampling tube)

± 4°F … < 392°F / 1 % reading > 392°F

Stack draft120 hPa± 0.02 or 1% reading
Differential pressure120 hPa± 0.02 or 1% reading
Gas flow velocity measurement1 … 100 m/s (using Pitot tube)

± 1 m/s (<2 m/s) ± 0.2 m/s (2…10 m/s)

± 0.5% (>10 m/s)

 

Calculated valuesRangeCalculated valuesRange
Carbon dioxide0 … CO2 max.Air Ratio (Lambda)1 … 9.99
Heat losses qA0 … 99.9 %Excess Air0 … 99.9
Efficiency0 … 120 %CO/CO2 ratio0 … 10

 

GENERAL SPECIFICATIONS
Max suction range gas pump350 hPa
Typical gas flow23.8 gal/h (90 l/h)
Internal memory16.000 data storage
Data transmissionvia USB
InterfacesSD card reader, USB, Bluetooth
Display3.5″ TFT color display
Operation temperature41°F …. 113°F (5 … 45°C) max. 95 % RH, none condensing
Storage temperature-4°F ….. 122°F (-20°C … 50°C)
Ambient conditionsnot in aggressive, corrosive or high dust ambience, not for use in hazardous areas
Battery operated

Lithium-Ion battery, 10 h operation time (Base unit without gas cooler and soot probe)

Lithium- Ion battery, 25 h Operation time (Remote Control Unit)

Grid power supply100 – 240 V AC / 50 … 60 Hz 1.4A
Protection class

IP 30 of base unit

IP 20 of base unit open

Weightapprox. 16.3 lbs.
Dimensions(W x H x D) 18.5“ x 9” x 12” complete unit
TÜV approvalByRgG 280 acc. 1. BImSchV and EN 50379

 

Download Brochure USDownload Brochure MEX