SWG 100 BIOGAS Analyzer
SWG 100 BIOGAS Details
SWG 100 BIOGAS Application
SWG 100 BIOGAS EX Cabinet 00
SWG 100 BIOGAS EX Cabinet 01
SWG 100 BIOGAS EX Cabinet 03

SWG 100 Biogas – Stationary Biogas Analyzer

$15,545.00

SWG 100 BIOGAS Analyzer
SWG 100 BIOGAS Details
SWG 100 BIOGAS Application
SWG 100 BIOGAS EX Cabinet 00
SWG 100 BIOGAS EX Cabinet 01
SWG 100 BIOGAS EX Cabinet 03
Power up your biogas production with our stationary analyzer – 24/7 Monitoring, Always Reliable
  • Available with and without UL/CSA certification
  • Also available with UL/CSA EX ZONE 2 CABINET
  • Up to 10 sites monitoring via. time sharing
  • Auto calibration
  • Sampling flow from low suction up to high pressure gas

  • (*2) NOTE: as stand-alone or in combination with #12269 plus #66051 or combined with #12117 dilution system
  • (*4) NOTE: the sensor can be used stand-alone or together with #12117 dilution system or with #12269
  • (*5) NOTE: use only in combination with H2 immune H2S sensor

NOTE: Only for mounting at wet & dirty sampling point with condensate higher than 14ml/min.
ADD one for each additional sampling point MAX 9.


Incl. external control via 4x contacts and 4channel analog input 4-20mA
Note: recommended is using one module for each sampling point. One module for each port.

Select Quantity in Meters. 9 additional ports can be added.

(client scope)

Product total
Options total
Grand total
SWG 100 BIOGAS Analyzer
SWG 100 BIOGAS Details
SWG 100 BIOGAS Application
SWG 100 BIOGAS EX Cabinet 00
SWG 100 BIOGAS EX Cabinet 01
SWG 100 BIOGAS EX Cabinet 03

SWG 100 Biogas – Stationary Biogas Analyzer

$15,545.00

SWG 100 BIOGAS Analyzer
SWG 100 BIOGAS Details
SWG 100 BIOGAS Application
SWG 100 BIOGAS EX Cabinet 00
SWG 100 BIOGAS EX Cabinet 01
SWG 100 BIOGAS EX Cabinet 03
Power up your biogas production with our stationary analyzer – 24/7 Monitoring, Always Reliable
  • Available with and without UL/CSA certification
  • Also available with UL/CSA EX ZONE 2 CABINET
  • Up to 10 sites monitoring via. time sharing
  • Auto calibration
  • Sampling flow from low suction up to high pressure gas

  • (*2) NOTE: as stand-alone or in combination with #12269 plus #66051 or combined with #12117 dilution system
  • (*4) NOTE: the sensor can be used stand-alone or together with #12117 dilution system or with #12269
  • (*5) NOTE: use only in combination with H2 immune H2S sensor

NOTE: Only for mounting at wet & dirty sampling point with condensate higher than 14ml/min.
ADD one for each additional sampling point MAX 9.


Incl. external control via 4x contacts and 4channel analog input 4-20mA
Note: recommended is using one module for each sampling point. One module for each port.

Select Quantity in Meters. 9 additional ports can be added.

(client scope)

Product total
Options total
Grand total

Description

 

ANALYZER COMPARISON CHARTBIOGAS ANALYZERBIOGAS ANALYZER UL LISTEDLANDFILL ANALYZERBIOGAS METHANE ANALYZER
STANDARD ANALYZER CONFIGURATION# 951002# 951006UL# 951002LFG# 951030
regulated sample gas pump with sample gas flow monitoring and adjustment
filtration of sample gas and of acid gases before internal sample flow sensor
sampling from low suction -100mbar up to +250mbar (including OPTION 12652)
solenoid valve for auto-zero (with clean ambient air) and for automatic calibration using permanently attached gas mixture cylinder (user scope of supply)
sample gas supply cut-off in case of system alarm, using “fail-safe” solenoid valve (normally closed), including one sample gas sampling inlet port
all stainless steel gas connectors 1/8”ID threads, with 6mm bulkhead compression fittings (also replaceable by user)
stainless steel adapter 1/8”I – 1/8”O, with flow restrictor orifice, to be mounted at sample gas inlet from high pressure sampling
human machine interface with color TFT display, keyboard and RS485 interface (Modbus RTU)
all password protected, intuitive software guided menu, with diagnosis software and logbook
External Main Switch
UL Certified
ON SITE START UP SUPPORT (UL MANDATORY)
Dilution system 1:50 for continuous measurement of H2S sample gas

Features:

  • Stationary biogas analyzer
  • Analyzer for biogas, bio-methane, landfill-gas, coal bed methane
  • Customizable for your needs and applications!

Benefits:

  • Make your biogas process more cost-effective.
  • Get the data to show your organization cares about the environment.

Applications:

Bio Gas / Landfill / CHP, Biogas / Landfill / CHP, CH4, CO, CO2 Measured, H2, H2S, O2, simple

  • THE UNIQUE ANALYZER
  • for Bio-gas, Bio-methane, Landfill-gas, Coal bed Methane
  • SWG 100 – BIOGAS – Instrument main features are:
  • industry compatible rugged design for harsh industrial environment
  • standard system safety included with continuously monitored fan ventilation of cabinet,
  • gas flow restrictor orifice at gas inlet
  • efficient sample gas preparation for fast and reliable measurements
  • sampling from low suction up to high pressure gas
  • no dilution of the sample gas, neither use of compressed air is required
  • direct and continuous/discontinuous measurement, with pressure and temperature compensation and event data logging
  • up to 10 sites monitoring (time sharing technique) with only one analyzer
  • ready to run delivery
Measured componentsMeasuring methodMeasuring rangeResolutionAccuracy
Methane CH4infrared0 … 100%0.1 Vol%± 0.3 Vol% / 3 % of reading**
Carbon dioxide CO2infrared0 … 100%0.01 Vol%± 0.3 Vol% / 3 % of reading**
Oxygen O2ec, continously0 … 25%0.01 Vol%0.2 % abs.
Hydrogen sulfide H2Sec, discontinously0 – 2,000/4,000 ppm1 ppm± 10 ppm / 10 % of reading**
Hydrogen sulfide H2S lowec, discontinously0 – 200/1,000 ppm1 ppm± 5 ppm / 10 % of reading**
Hydrogen H2ec, discontinously0 – 1,000/2,000 ppm1 ppm± 10 ppm / 10 % of reading**
Carbon monoxide COec, discontinously0 – 10,000/20,000 ppm1 ppm± 10 ppm / 3 % of reading**

 

H2S dilution systems 50:1

for landfills and other high H2S applications, not only has the range been extended, but additionally, high resiliency sensors can be used providing better accuracy and stability, especially in difficult applications such as landfills, dairy digesters, etc.

 

Calculated componentCalorific value: 0 – 50 MJ/m3; MJ/kg
HMI human machine interface

3.5” TFT color display

Backlit keyboard, password protected operation

4x analog output 4-20 mA, floating, max. load 500R

2 alarm relays, potential free contacts 24 Vdc/5 A

RS485 digital interface (Modbus RTU)

DIN-rail RS485 / Profibus converter

System safety components

Monitored cabinet ventilation fan with alarm

Stainless steel flow restrictor orifice

Sample gas shut-down solenoid valve

LEL (CH4) monitoring inside cabinet (option)

Sample preparation

Stainless steel gas fittings with 1/8” ID threads

Electric gas cooler (Peltier type) (option)

Teflon particulate filter, internal Viton hosing

Sampling biogas with condensate of max. 14ml/min

Monitored and regulated sample flow 40…60 l/h

Sample inlet pressure: -40 inH2O to +80 inH2O (-100 mbar to +200 mbar)

Sample venting: atmosphere pressure

Cabinet dimensions

Aluminum with anti-corrosive structural painting

27.55″ x 23.61″ x 8.26″ (700 x 600 x 210 mm) ( H x W x D ) for wall or rack mounting

Weight / Protection55lbs (25kg) / IP54
Ambient temperature41°F …113°F (+5°C…+45°C) or 14°F …113°F (-10°C…+45°C) with cabinet heater
Installation siteIndoor or outdoor (rain and sun shade is mandatory user scope of supply)
Cabinet conditioning

Continuous, monitored fan ventilation

Cabinet heater 200 W (option)

Power supplyUniversal 90 – 240 Vac / 47 – 63 Hz / 90 W (300 W with cabinet heater)

 

Download Brochure USDownload Questionnaire USDownload Brochure MEX

 