When you need a reliable CEMS system for continuous emissions monitoring and stationary gas analysis, MRU Instruments offers professional gas analyzer solutions designed for demanding industrial applications. Our stationary gas analyzer systems can measure and monitor a variety of gases in real time, providing valuable information for emissions monitoring, combustion analysis, process control, and environmental applications.
MRU Instruments offers technology for applications ranging from biogas and renewable natural gas to industrial combustion and emissions monitoring. A properly configured CEMS system can provide continuous gas measurements and help facilities monitor emissions, evaluate combustion performance, and maintain detailed records of gas concentrations.
A CEMS system, or Continuous Emissions Monitoring System, is designed to continuously measure gases released from industrial and combustion processes. Depending on the configuration, a CEMS system may monitor gases such as oxygen (O₂), carbon monoxide (CO), carbon dioxide (CO₂), sulfur dioxide (SO₂), nitrogen oxides (NOₓ), and other gases.
Stationary gas analyzers are an important component of many CEMS systems. They provide ongoing measurements that can be used for emissions monitoring, process optimization, combustion control, and applicable environmental reporting requirements.
MRU Instruments’ stationary gas analyzers are designed for applications where continuous or long-term gas measurement is required. These systems can be used to analyze combustion gases, process gases, biogas, landfill gas, and other industrial gas streams.
A stationary gas analyzer can provide continuous measurement without requiring technicians to repeatedly perform manual sampling. This makes stationary systems useful for facilities that need ongoing information about gas concentrations and process conditions.
An emission analyzer can be incorporated into a CEMS system to measure specific pollutants and combustion gases. The appropriate analyzer configuration depends on the application, gases being measured, expected concentrations, sampling conditions, and monitoring requirements.
CEMS equipment may also incorporate sample probes, sample conditioning systems, pumps, calibration systems, and data acquisition equipment. Together, these components allow the system to collect a representative sample, analyze the gas, and record the resulting measurements.
Stationary gas analyzer technology can also be used for biogas and other process gas applications. Biogas analyzer systems can measure important components such as methane (CH₄), carbon dioxide (CO₂), oxygen (O₂), and hydrogen sulfide (H₂S), depending on the instrument and application.
For facilities that require ongoing gas measurement, stationary systems can provide continuous monitoring of gas composition and process conditions. This information can help operators evaluate gas quality, process performance, and equipment operation.
MRU Instruments has provided professional gas analysis technology since 1984. Our stationary gas analyzers and emissions monitoring solutions are designed for users who require dependable measurements in industrial and commercial environments.
When selecting a CEMS system, it is important to consider the gases being measured, required measurement ranges, sample conditions, monitoring frequency, and the specific requirements of the application. MRU Instruments can help you identify the appropriate gas analysis technology for your needs.
Click any of our stationary gas analyzer products below to view additional information, specifications, and measurement capabilities. If you need more information about a CEMS system, emission analyzer, stationary gas analyzer, or another MRU Instruments product, visit our Applications or Download pages for additional resources.
You can also contact MRU Instruments for assistance selecting the right system. Our knowledgeable staff can help you evaluate your application and determine which stationary gas analyzer or CEMS system best fits your measurement requirements.
Complete CEM system for emissions monitoring dual heat exchanger M&C Peltier gas cooler with double…
Complete CEM system for emissions monitoring dual heat exchanger M&C Peltier gas cooler with double automatic condensate draining pumps Efficient sample gas filtration using PTFE sintered particulate filter Condensate monitoring and alarm on display and gas sampling stop in case of alarm Filtration of acid gases to protect the internal sample gas flow sensor
Rugged, Low-Cost Industrial Gas Analyzer Use of optimized NDIR technology with improved accuracy and without…
Rugged, Low-Cost Industrial Gas Analyzer Use of optimized NDIR technology with improved accuracy and without zero offset Automatic calibration for up to 4 gas cylinders Double stage Peltier gas cooler with 2 automatic condensate pumps Cold/dry gas sampling with low sample flow volume of only 1 l/min
Stationary Analyzer for Continuous Emission Monitoring up to 6 gas simultaneous measurement Advanced sample gas…
Stationary Analyzer for Continuous Emission Monitoring up to 6 gas simultaneous measurement Advanced sample gas preparation for fast and reliable measurements Simple installation, ready to run delivery and easy to maintain. Heated gas sampling probe