SWG 200 – Continuous Emission Monitor

SWG 300 CEMS Probes 003
SWG 300 CEMS Probes 004
SWG 300 CEMS Probes 002
SWG 300 CEMS Probes 005
SWG 200 CEM Probes 001
Rugged, Low-Cost Industrial Gas Analyzer
  • Use of optimized NDIR technology with improved accuracy and without zero offset
  • Automatic calibration for up to 4 gas cylinders
  • Double stage Peltier gas cooler with 2 automatic condensate pumps
  • Cold/dry gas sampling with low sample flow volume of only 1 l/min

Description

HIGH END 24/7 gas analysis
With SWG 200 CEM (Continuous Emission Monitoring) we offer you a cost-effective, reliable system for emission and combustion monitoring.

Features:

  • Use of optimized NDIR technology with improved accuracy and without zero offset
  • O₂ measurement with an electrochemical or a paramagnetic sensor
  • Automatic zeroing using clean ambient air
  • Automatic calibration for up to 4 gas cylinders
  • Double-stage Peltier gas cooler with 2 automatic condensate pumps
  • Cold/dry gas sampling with low sample flow volume of only 1 l/min

Benefits:

  • Make your combustion process more cost-effective.
  • Get the data to show your organization cares about the environment.

Applications:

Diesel engines, methane/natural gas boilers, landfill gas/bio-gas CHPs, bagasse and biomass boilers and others.

 

Additional information

NO2

NDIRplus

O2

ECS / PM

SO2

ECS / NDIR

SWG200-CEM stationary gas emissions analyzer with:

  • IP54 aluminum cabinet with anti-corrosive red structural lacquer and monitored fan ventilation
  • Included dual heat ex changer Peltier gas cooler with two automatic condensate draining pumps
  • Efficient sample gas filtration using PTFE sintered particulate filter
  • Regulated sample gas pump with sample gas flow monitoring and alarm
  • Filtration of acid gases to protect the internal sample gas flow sensor
  • Solenoid valve for auto-zero with clean ambient air
  • Solenoid valve for calibration gas, with aluminum fine pressure regulator at cal. gas inlet port
  • Human machine interface with color TFT display, keyboard and standard RS485 interface (Modbus RTU)
  • All password protected, intuitive software guided menu, with diagnosis software and logbook
  • Power supply analyzer only 230Vac / 47-63Hz / 90W (110Vac power supply on request)
  • Total length of all heated sampling lines more than 60m, requires 3-phase power supply (L1 ; L2 ; L3 ; N ; PE)
  • Clean indoor mounting place, preferably air conditioned
  • Outdoor mounting place in clean, 41°F to 113°F (+5°C to 45°C) ambient, with mandatory sun & rain protection (user scope)
Gas measurement (NDIR) Measuring range min./max. Resolution Repeatability 8h-Drift Linearity
NO Nitric oxide 0 … 200 / 4,000 ppm 0.1 ppm 2 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
NO2 Nitric dioxide 0 … 150 / 1,000 ppm 0.1 ppm 1 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
SO2 Sulfur dioxide 0 … 150 / 4,000 ppm 0.1 ppm 2 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
CO2 Carbon dioxide 0 … 50% 0.01% 0.2 % or 1 % reading 0.2 % or 1 % reading 1 % m. r.
CO Carbon monoxide 0 … 175 / 10,000 ppm 0.1 ppm 2 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
N2O Nitrous dioxide 0 … 100 / 500 ppm 0.1 ppm 2 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
CH4 Methane 0 … 500 / 10,000 ppm 0.1 ppm 10 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
C3H8 Propane 0 … 200 / 5,000 ppm 0.1 ppm 2 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.

 

Gas measurement (EC/PM) Methode Measuring range min./max. Resolution Accuracy
O2 Oxygen (Long Life) EC 0 … 25 % 0.01% 0.25%
O2 Oxygen PM 0 … 25 % 0.01% 0.1%
H2S Hydrogen sulfide EC 0 … 2,000/5,000 ppm 1 ppm +/- 5 ppm or 5 % reading
H2 Hydrogen EC 0 … 1,000/2,000 ppm 1 ppm +/- 5 ppm or 5 % reading

 

General technical data  
Zero offset                        negligible due to automatic zeroing
Span offset less than 0.2 % of the measuring range per month
Calculated components

NOx: NO + NO2, calculated ppm or mg/m3, user-selectable O₂ reference combustion calculations (efficiency, heat loss) on special request

Operation/interfaces
  • Backlit 3.5″ TFT color display
  • Backlit keyboard, password-protected operation
  • 4 analog outputs 4 … 20 mA, galvanically isolated, max. load: 500 R
  • 2 alarm relays, potential-free contacts: 24 Vdc, 5 A
  • Data storage and data logger on SD card
  • RS 485 digital interface (Modbus RTU)
  • DIN rail RS 485, to ProfiBus converter or to Ethernet converter
Gas conditioning
  • HD gas sampling probe, heated ceramic filter with back purge, or gas sampling probe HD-GW, heated glass wool filter, or LD gas sampling probe, unheated with in-situ sintered metal filter, heated or unheated gas sampling line, PTFE DN 4/6 mm
  • Thermoelectric gas cooler (Peltier) with constant +4 °C dew point
  • Teflon particle filter, internal Viton tubing
  • Monitored and regulated gas sampling pump
  • Constant gas flow of 50 l/h
  • Gas inlet pressure: –80”H2O … 80”H2O (–200 … +200 mbar (hPa))
  • Sample gas outlet: atmospheric pressure
Enclosure Stainless steel cabinet, continuously monitored cabinet ventilation with alarm, Antifreeze heater 200 W (option)
Operating conditions 41 … 113 °F (+5 … +45 °C) or 14 … 113 °F (-10 … +45 °C) with cabinet heating
Power supply Universal: 90 … 240 Vac, 47 … 63 Hz, 120 W (420 W with heating)
Protection class IP54
Dimensions (W x H x D) 27.55” x 12.61” x 8.26” (700 x 600 x 210 mm), suitable for wall mounting
Weight 110 lbs. (50 kg)

 