CALL US: (832) 230-0155

SWG 100 CEM Probes 1

SWG 100 CEM – Continuous Emission Monitor

SWG 100 CEM Probes 1
Stationary Analyzer for Continuous Emission Monitoring
  • up to 6 gas simultaneous measurement
  • Advanced sample gas preparation for fast and reliable measurements
  • Simple installation, ready to run delivery and easy to maintain.
  • Heated gas sampling probe

Description

With the SWG 100 CEM (Continuous Emission Monitoring) we offer you a cost-effective, reliable system for emission and combustion monitoring.
With simultaneous infrared analysis of up to 3 flue gas components is possible.
Furthermore, it is possible to measure 3 more components simultaneously electrochemically.
Alternatively, up to 5 components may be measured simultaneously on an electrochemical basis.
The electrochemical sensors are O2 – CO – NO – NO2 – SO2.

Benefits:

  • Make your combustion process more cost-effective.
  • Get the data to show your organization cares about the environment.

Applications:

Breweries, Cement Industry, Gas Turbines, Compressor Stations, Steel Industry, Power Plants, Refineries, Universities / Laboratory

 

 

  • very compact industrial design, for up to 6 gas simultaneous measurement
  • use low cost but reliable electro-chemical cells for O2, CO, NO, NO2, SO2
  • and infrared module (NDIR) for CO2 / CH4 / CO / C3H8 measurement
  • advanced sample gas preparation for fast and reliable measurements
  • flexible platform can be used for various combustion applications
  • direct and continuous/discontinuous measurement, with pressure and temperature compensation of all main flue gas parameters
  • external measurements (temperature, pressure, etc.) by reading of ext. standard signal
  • simple installation, ready to run delivery and easy to maintain
Gas measurement (NDIR) Measuring range min./max. Resolution Repeatability*
CO Carbon monoxide 0 … 1,000/100,000 ppm 1 ppm ± 10 ppm or 3 % reading
CO2 Carbon dioxide 0 … 50 % 0.01 Vol % ± 0.1% or 3 % reading
SO2 Sulfur dioxide 0 … 1,000/10,000 ppm 1 ppm ± 10 ppm or 3 % reading
CH4 Methane 0 … 1,000/40,000 ppm 1 ppm ± 10 ppm or 3 % reading
C3H8 Propane 0 … 1,000/20,000 ppm 1 ppm ± 10 ppm or 3 % reading

 

Gas measurement (EC/PM) Measuring range min./max. Resolution Repeatability*
O2 Oxygen (long life) EC 0 … 25 % 0.01 % ± 0.25 % abs.
O2 Oxygen PM 0 … 25 % 0.01 % ± 0.1 % abs.
CO Carbon monoxide EC 0 … 10,000/20,000 ppm 1 ppm ± 10 ppm or 5 % reading
NO Nitric oxide EC 0 … 1,000/5,000 ppm 1 ppm ± 5 % or 5 % reading
NO2 Nitrogen dioxide EC 0 … 200/1,000 ppm 1 ppm ± 5 % or 5 % reading
SO2 Sulfur dioxide EC 0 … 2,000/5,000 ppm 1 ppm ± 10 ppm or 5 % reading

 

General technical data
Zero offset negligible due to automatic zeroing
Span offset less than 0.2 % of the measuring range per month
Calculated components

NOx: NO + NO₂, calculated ppm or mg/m3, user-selectable O₂ reference combustion calculations (efficiency, heat loss) on special request

Operation/interfaces

·          Backlit 3.5″ TFT color display

·          Backlit keyboard, password-protected operation

·          4 analog outputs 4 … 20 mA, galvanically isolated, max. load: 500 R

·          2 alarm relays, potential-free contacts: 24 Vdc, 5 A

·          Data storage and data logger on SD card

·          RS 485 digital interface (Modbus RTU)

·          DIN rail RS 485, to ProfiBus converter or to Ethernet converter

Gas conditioning

·          HD gas sampling probe, heated ceramic filter with backpurge, or gas sampling probe HD-GW,

           heated glass wool filter, or LD gas sampling probe, unheated with in-situ sintered metal filter,

           heated or unheated gas sampling line, PTFE DN 4/6 mm

·          Thermoelectric gas cooler (Peltier) with constant +4 °C dew point

·          Teflon particle filter, internal Viton tubing

·          Monitored and regulated gas sampling pump

·          Constant gas flow of 50 l/h

·          Gas inlet pressure: – 150 … + 50 mbar (hPa)

·          Sample gas outlet: atmospheric pressure

Enclosure Stainless steel cabinet
Dimensions (W x H x D) 24” x 28” x 9” (600 x 700 x 210 mm), suitable for wall mounting
Weight 110 lbs. (50 kg)
Operating conditions 41°F … 113°F or 14°F … 113°F (+5 … + 45 °C or – 10 … + 45 °C) with cabinet heating
Power supply Universal: 100 … 240 Vac, 47 … 63 Hz, 120 W (420 W with cabinet heating)
Protection class IP54

 

Download Brochure US Download Industrial Probes Download Brochure MEX

TEST