Best-in-class flue gas emission analyzer for long time measurements of industrial combustions
  • Precise and very stable non dispersive infrared (NDIR) technique, for enhanced long time measurements.
  • Up to 8 gas NDIR measurement
  • Remote control via smartphone or tablet

Description

Features:

  • Flue gas emission analyzer for long-time measurements of industrial combustions, large boilers, gas engines and turbines, furnaces, and many more

Benefits:

  • Make your combustion process more cost-effective.
  • Get the data to show your organization cares about the environment.

Applications:

Gas turbines, compressor, Glass industry, Iron and Steel industry, Refineries, Petrochem, Universities, Laboratory

  • Precise and very stable offset measuring technique using special non dispersive infrared (NDIR) technique, for enhanced long time measurements
  • Up to 8 gas NDIR measurement:
    CO/CO2/C3H8/CH4/SO2/NO/NO2/N2O and oxygen with either long-life O2-ECS or
    O2-PM (paramagnetic cell)
  • Remote display through MRU4U App over bluetooth on smartphone or tablet or trough VCN server via LAN/WLAN
  • 7” high-resolution (800×480 pixel) TFT color display with swipe and touch technique as for smartphones, with LINUX operating system
  • Intuitive icons and country specific language on display
  • Modern and robust design, Aluminum enclosure with rubber molded impact
    protection for use in harsh industrial environment
  • Advanced algorithms to control analyzer’s operation, like warming up, compensation of cross-sensitivity values, response time – all which have impact on the quality and performance
  • Measurement of many additional parameters:
    temperatures (ambient and flue gas), pressures (atmospheric and differential),
    internal sample flow monitoring
  • Measurement of flue gas flow velocity (using of Pitot tube) and calculation of
    stack gas flow rate
  • Calculation of all combustion parameters like:
    heat loss, combustion efficiency, excess air coefficient, dew point temperature and others
  • Results stored in database – possibility to view entire measurement session in graphical form, create measurement reports, export data to CSV files, and more
  • PC communication via LAN – Ethernet
  • Wireless data transfer via Bluetooth dongle or WLAN dongle
  • Long distance data transfer via RS485 cable
  • Analog outputs (8-channels), analog inputs (4-channels)
  • SAMPLE GAS CONDITIONING: Dual gas cooler (Peltier) with dual condensate
    draining pumps, with constant dew point +5°C
    when connected to mains power supply
  • Condensate monitoring and alarm on display
  • Strong gas sampling pump, regulated flow of approx 1l/min
  • Gas sampling probe heated, with exchangeable probe tubes, including K-type thermo-couple for flue gas temperature measurement
  • Heated sampling line, Teflon 6/4mm, 9.84′ or 16.4′ or 32.81′ (3 m – 5 m – 10 m) and other lengths
TECHNICAL DETAILS
Gas measurement (NDIR) Measuring range min./max. Resolution Repeatability 8h-Drift Linearity
NO Nitric oxide 0 … 200 / 4,000 ppm 0.1 ppm 2 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
NO2 Nitric dioxide 0 … 300** / 1,000 ppm 0.1 ppm 5 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
SO2 Sulfur dioxide 0 … 300** / 4,000 ppm 0.1 ppm 5 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
CO2 Carbon dioxide 0 … 50% 0.01% 0.2 % or 1 % reading 0.2 % or 1 % reading 1 % m. r.
CO Carbon monoxide 0 … 175 / 10,000 ppm 0.1 ppm 2 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
N2O Nitriuos dioxide 0 … 100 / 500 ppm 0.1 ppm 2 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
CH4 Methane 0 … 500 / 10,000 ppm 0.1 ppm 10 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
C3H8 Propane 0 … 200 / 5,000 ppm 0.1 ppm 2 ppm or 1 % reading 2 ppm or 1 % reading 1 % m. r.
Gas measurement (EC/PM) Methode Measuring range Resolution Accuracy
O2 Oxygen (Long Life) EC 0 … 25 / 100% 0.01% 0.20% absolute
O2 Oxygen PM 0 … 25 / 100% 0.01% 0.1%

 

Other measurements Methode Measuring range Resolution Accuracy
Stack temperature T-GAS NiCrNi 0 … 1.100 °C 1 °C ± 2 °C or 2 % reading
Combustion air temperature T-AMB NiCrNi 0 … 100 °C 1 °C ± 1 °C or 1 % reading
Differential pressure P Piezoresistive -120 … +120 hPa 1 Pa ± 2 Pa or 1 % reading
Flow velocity measurement V Pitot 3 … 100 m/s 0.1 m/s ± 1 m/s or 1 % reading
Standardized ext. signal AUX Software for K-thermocouple, 0 … 10 Vdc, 4 … 20 mA, RS 485
Combustion calculations (fuel type depend.) Software Losses, ExcAir, Air Ratio, dew point, CO₂
Emission calculations   Software mg / Nm3, reference of O₂

 

General technical data  
Operating system Linux
Display, operation 7″ TFT (800 x 480 px) colour display, backlit, with touch pad
Data storage dynamic, internally 10,000 data sets, external USB stick
Interface to PC/notebook Ethernet, WiFi, RS 485
Communication interfaces RS 485, RJ45 (Ethernet), WiFi, Bluetooth
Printer external USB/WiFi printer
Analog output/input 4 … 20mA 8 channel out, 4 channel in, user configurable
Universal analog input (AUX) 0 … 10 Vdc, 4 … 20 mA, NiCrNi-thermocouple, RS 485
System warm up time 30 minutes, typical
Mains free operation time Li-Ion, 96 Wh, for standby 1 hour
Operating conditions 41 … 113 °F (+5 … +45 °C); RH up to 90 % non condensing
Storage temperature -4 … 122 °F (-20 … +50 °C)
Power supply 86 … 265 Vac, 47 … 63 Hz, 105 W (up to 600 W with heated gas sample line)
Protection class IP20 (or IP42 inside transport case)
Dimensions (W x H x D) 16.92″ x 11.41″ x 5.90″ (430 x 290 x 150 mm)
Weight approx. 22lbs. (10 kg) device only, approx. 22 lbs. (10 kg) per bag (1x device and 1x accessories)

 

Data subject to change without notice. | 1 EC = elektrochemical sensor, PM = paramagnetic sensor, NDIR = non-dispersive infrared spectroscopy | * which ever is larger | **150 ppm possible with optional APE-box | N-12744-K2-0,5M-0821

Download Brochure US Download Probes Download Questionnaire Download Brochure MEX