SWG 100 SYNGAS – Analyzer

SYNG SWG 100 Interior
SYNG SWG 100 Application
Designed for use in industrial safe areas or inside laboratories as well
  • IP54 stainless steel cabinet, also for use in outdoor condition with sun and rain cover
  • Multiple sampling point monitoring (up to 8 sites monitoring) with one analyzer
  • H₂ thermal conductivity detector measurement with cross interference correction
  • NDIR bench for CO-CO₂-CH₄ analysis (using selective CH₄ measurement)
  • H₂S electrochemical cell measurement, H₂ immune
  • Sample gas washing device, for tar free sample gas

Description

Features:

  • Designed for use in industrial safe areas or inside laboratories as well
  • Can be installed in outdoor or indoor location
  • Can sample dry or wet syngas
  • Can sample pressurized or low pressure gas
  • Can be used from single or double sampling points.

Benefits:

  • Make your combustion process more cost-effective.
  • Get the data to show your organization cares about the environment.

Applications:

CH4, CO, CO2 Measured, Continuous Emission Monitoring, Iron / Steel Industry, O2, Process / Syngas, simple, Universities / Laboratory

The complete, ready to use  analyzer SWG100 Syngas  
is the industrial solution for:

  • biomass, coal and waste  gasification plants
  • cogeneration heat and power engines (CHP) using syngas
  • small scale syngas analysis for research institutes and lab

WITH

  • IP 54 stainless steel cabinet, also for use in outdoor conditions with sun and rain cover
  • accurate measurements, using infrared and thermal conductivity technology
  • sampling from low suction -100mbar up to high pressure +200mbar of gas pipe
  • no dilution of sample gas is required
  • integrated gas cooler with condensate draining pump
  • direct and continuous measurement, with pressure and temperature compensation
  • multiple sampling point monitoring  (up to 8 sites monitoring) with one analyzer
  • flow restrictor orifice gas inlet for high-pressure site
  • with sample gas cut-off and power supply shut-off in case of alarm
  • industry compatible rugged design, easy and fastest service design

 

Measured components Method Range Resolution Accuracy
CO Carbon Monoxide NDIR 0 … 100% 0.01 Vol.-% 0.2 Vol-% or 2% reading**

or 0.1 % of reading after calibration**

CO2 Carbon Dioxide NDIR 0 … 100% 0.01 Vol.-% 0.2 Vol-% or 1% reading**

or 0.1 % of reading after calibration**

CH4 Methane NDIR 0 … 100% 0.01 Vol.-% 0.2 Vol-% or 1% reading**

or 0.1 % of reading after calibration**

CO Carbon Monoxide NDIR 0 … 3,000 / 30,000 ppm 1 ppm ± 10 ppm or 3 % reading**
CO2 Carbon Dioxide NDIR 0 … 3,000 / 30,000 ppm 1 ppm ± 10 ppm or 3 % reading**
CH4 Methane NDIR 0 … 3,000 / 30,000 ppm 1 ppm ± 10 ppm or 3 % reading**
O2 Oxygen Electro-chemical 0 … 25% 0.01 Vol.-% 0.2% absolute
O2 Oxygen Paramagnetic 0 … 25% 0.01 Vol.-% 0.1% absolute
H2S Hydrogen Sulfide Electro-chemical 0 … 2,000 /5,000 ppm* 1 ppm 10 ppm or 10% reading**
H2 Hydrogen TCD 0 … 1.00 / 50% 0.01 % 0.2% or 2% reading**

 

Calculated values  
N2 Nitrogen Difference to 100%
Calorific value 0 … 50 MJ/m3 or MJ/kg

 

General technical data  
HMI                                                   (human machine interface)

 

3.5″ TFT color display
Keyboard, password protected operation
4 x analog output 4–20 mA, floating, max. load 500 R
4 x analog input 4–20 mA, passive inputs
2 alarm relays, potential free contacts 24 Vdc/5 A
RS485 digital interface (Modbus RTU)
System safety components Monitored cabinet atmosphere using Pellistor sensor for LEL detection

Stainless steel flow restrictor orifice

Sample gas shut-down solenoid valve

Power supply cut-off in case of system alarm

Sample conditioning Stainless steel gas fittings with 1/8″ ID threads

Electric gas cooler (Peltier) with constant dew point +5° C

Teflon particulate filter, internal Viton hosing

Sampling syngas with condensate of max. 14 ml/min

Monitored and regulated sample gas flow 60 l/h

Sample gas inlet pressure: –100 mbar to + 200 mbar

Sample gas venting: atmospheric pressure

Enclosure dimensions 27.55” x 23.61” x 8.26” (700 x 600 x 210mm) (H x W x D) for wall or rack mounting
Weight 99 lbs. (45 kg)
Protection class IP54, stainless steel
Operating conditions 41 … 113 °F (+5 … +45 °C) or 14 … 113 °F (-10 … +45 °C) with cabinet heating
Cabinet conditioning Cabinet heater 300 W
Power supply Universal 90–240 Vac / 47–63 Hz / 200 W, 500 W with heater
Installation site Indoor or outdoor (with sun/rain protection cover)

Download Brochure US

Download Brochure MEX 

Download Questionnaire

 