CALL US: (832) 230-0155

MGA Prime – Portable Reference Emission Analyzer

Best-in-class flue gas emission analyzer for long time measurements of industrial combustions
  • Precise and very stable non dispersive infrared (NDIR) technique, for enhanced long time measurements.
  • Up to 8 gas NDIR measurement
  • Remote control via smartphone or tablet

Description

Features:

  • Flue gas emission analyzer for long-time measurements of industrial combustions, large boilers, gas engines and turbines, furnaces, and many more

Benefits:

  • Make your combustion process more cost-effective.
  • Get the data to show your organization cares about the environment.

Applications:

C3H8, CH4, CO, CO2 measured, combustion portable, CxHy, gas turbines, compressor, glass industry, H2, H2S, iron industry, steel industry, mobile flue gas analysis, N2O, NO, NO2, NOx, O2, portable emissions analyzers, portable IR, refineries, petrochem, simple, SO2, universities, laboratory

  • Precise and very stable offset measuring technique using special non dispersive infrared (NDIR) technique, for enhanced long time measurements
  • Up to 8 gas NDIR measurement:
    CO/CO2/C3H8/CH4/SO2/NO/NO2/N2O and oxygen with either long-life O2-ECS or
    O2-PM (paramagnetic cell)
  • Remote display through MRU4U App over bluetooth on smartphone or tablet or trough VCN server via LAN/WLAN
  • 7” high-resolution (800×480 pixel) TFT color display with swipe and touch technique as for smartphones, with LINUX operating system
  • Intuitive icons and country specific language on display
  • Modern and robust design, Aluminum enclosure with rubber molded impact
    protection for use in harsh industrial environment
  • Advanced algorithms to control analyzer’s operation, like warming up, compensation of cross-sensitivity values, response time – all which have impact on the quality and performance
  • Measurement of many additional parameters:
    temperatures (ambient and flue gas), pressures (atmospheric and differential),
    internal sample flow monitoring
  • Measurement of flue gas flow velocity (using of Pitot tube) and calculation of
    stack gas flow rate
  • Calculation of all combustion parameters like:
    heat loss, combustion efficiency, excess air coefficient, dew point temperature and others
  • Results stored in database – possibility to view entire measurement session in graphical form, create measurement reports, export data to CSV files, and more
  • PC communication via LAN – Ethernet
  • Wireless data transfer via Bluetooth dongle or WLAN dongle
  • Long distance data transfer via RS485 cable
  • Analog outputs (8-channels), analog inputs (4-channels)
  • SAMPLE GAS CONDITIONING: Dual gas cooler (Peltier) with dual condensate
    draining pumps, with constant dew point +5°C
    when connected to mains power supply
  • Condensate monitoring and alarm on display
  • Strong gas sampling pump, regulated flow of approx 1l/min
  • Gas sampling probe heated, with exchangeable probe tubes, including K-type thermo-couple for flue gas temperature measurement
  • Heated sampling line, Teflon 6/4mm, 9.84′ or 16.4′ or 32.81′ (3 m – 5 m – 10 m) and other lengths
TECHNICAL DETAILS
Gas measurement (NDIR)Measuring range min./max.ResolutionRepeatability8h-DriftLinearity
NONitric oxide0 … 200 / 4,000 ppm0.1 ppm2 ppm or 1 % reading2 ppm or 1 % reading1 % m. r.
NO2Nitric dioxide0 … 300** / 1,000 ppm0.1 ppm5 ppm or 1 % reading2 ppm or 1 % reading1 % m. r.
SO2Sulpur dioxide0 … 300** / 4,000 ppm0.1 ppm5 ppm or 1 % reading2 ppm or 1 % reading1 % m. r.
CO2Carbon dioxide0 … 40%0.01%0.2 % or 1 % reading0.2 % or 1 % reading1 % m. r.
COCarbon monoxide0 … 175 / 10,000 ppm0.1 ppm2 ppm or 1 % reading2 ppm or 1 % reading1 % m. r.
N2ONitriuos dioxide0 … 100 / 500 ppm0.1 ppm2 ppm or 1 % reading2 ppm or 1 % reading1 % m. r.
CH4Methane0 … 500 / 10,000 ppm0.1 ppm10 ppm or 1 % reading2 ppm or 1 % reading1 % m. r.
C3H8Propane0 … 200 / 5,000 ppm0.1 ppm2 ppm or 1 % reading2 ppm or 1 % reading1 % m. r.

 

Gas measurement (EC/PM)MethodeMeasuring rangeResolutionAccuracy
O2Oxygen (Long Life)EC0 … 25 / 100%0.01%0.20% absolute
O2OxygenPM0 … 25 / 100%0.01%0.1%

 

Other measurementsMethodeMeasuring rangeResolutionAccuracy
Stack temperatureT-GASNiCrNi0 … 1.100 °C1 °C± 2 °C or 2 % reading
Combustion air temperatureT-AMBNiCrNi0 … 100 °C1 °C± 1 °C or 1 % reading
Differential pressurePPiezoresistive-120 … +120 hPa1 Pa± 2 Pa or 1 % reading
Flow velocity measurementVPitot3 … 100 m/s0.1 m/s± 1 m/s or 1 % reading
Standardized ext. signalAUXSoftwarefor K-thermocouple, 0 … 10 Vdc, 4 … 20 mA, RS 485
Combustion calculations(fuel type depend.)SoftwareLosses, ExcAir, Air Ratio, dew point, CO₂
Emission calculations Softwaremg / Nm3, reference of O₂

 

General technical data 
Operating systemLinux
Display, operation7″ TFT (800 x 480 px) colour display, backlit, with touch pad
Data storagedynamic, internally 10,000 data sets, external USB stick
Interface to PC/notebookEthernet, WiFi, RS 485
Communication interfacesRS 485, RJ45 (Ethernet), WiFi, Bluetooth
Printerexternal USB/WiFi printer
Analog output/input 4 … 20mA8 channel out, 4 channel in, user configurable
Universal analog input (AUX)0 … 10 Vdc, 4 … 20 mA, NiCrNi-thermocouple, RS 485
System warm up time30 minutes, typical
Mains free operation timeLi-Ion, 96 Wh, for standby 1 hour
Operating conditions41 … 113 °F (+5 … +45 °C); RH up to 90 % non condensing
Storage temperature-4 … 122 °F (-20 … +50 °C)
Power supply86 … 265 Vac, 47 … 63 Hz, 105 W (up to 600 W with heated gas sample line)
Protection classIP20 (or IP42 inside transport case)
Dimensions (W x H x D)16.92″ x 11.41″ x 5.90″ (430 x 290 x 150 mm)
Weightapprox. 22lbs. (10 kg) device only, approx. 22 lbs. (10 kg) per bag (1x device and 1x accessories)

 

Data subject to change without notice. | 1 EC = elektrochemical sensor, PM = paramagnetic sensor, NDIR = non-dispersive infrared spectroscopy | * which ever is larger | **150 ppm possible with optional APE-box | N-12744-K2-0,5M-0821

Download Brochure US Download Brochure MEX

Download Probes 

Download Questionnaire