CALL US: (832) 230-0155

NOVA Compact – Combustion Analyzer

Simultaneous measurements of up to 4 gas components
  • Very compact and extremely rugged gas analyzer
  • Fully equipped for all kind of adjustment and monitoring tasks at combustion
  • Intuitively and comfortable to use.

Description

Features:

  • Combustion gas analyzer
  • The ultimate robust and compact analyzer for professionals
  • Simultaneous measurements of up to 4 gas components

Benefits:

  • Make your combustion process more cost-effective.
  • Get the data to show your organization cares about the environment.

Applications:

Breweries, cement industry, CO, CO2 calculated, combustion portable, boiler installers, boiler manufacturers, iron industry, steel industry, mobile flue gas analysis, NO, NOx, O2, portable gas analyzers simple

  • Simultaneous measurements of up to 4 gas components!
  • Gas temperature measurement up to 2,012°F (use stainless steel up to 1,200°F, use Inconel tubes up to 2,012°F)
  • Large condensate separator with PTFE (Teflon) coated filter (Optional with gas cooler)
  • Air purging pump for CO-sensor protection
  • Built-in printer with easy paper loading
  • Internal data storage for up to 16,000 measurements!
  • Battery and grid power operation:
  • High energy Li-Ion battery (up to 10 hours operation time / with gas cooler approx. 2 – 3 hrs.)
  • Wall-plug, universal grid power supply, 100-240Vac/50-60Hz / 12V dc
  • Color backlit TFT display
  • Durable and dirt resistant LED lit keypad
  • Compact and robust transport case

Warranty – 3 Years on the analyzer and accessories

(2 years on O2 sensor – 1 year on other gas sensors)

Measurement componentMeasuring rangeResolutionAccuracy
O2Oxygen (Long Life)0 … 21%0.1 %± 0.2 Vol-% abs.
COCarbon monoxide

(H2 Compensated)

0 … 10,000 / 20,000 ppm *1 ppm± 20 ppm or 5 % reading < 10,000 ppm  /

10 % reading > 10,000 ppm

COCarbon monoxide (low)0 … 500 with **0.1 ppm± 2.0 ppm or 5 % reading
COCarbon monoxide0 … 40,000 / 100,000 ppm *1 ppm± 0.02% or 5 % reading < 0.4% / 10 % reading > 0.4%
NONitric oxide0 … 1,000 / 5,000 ppm *1 ppm± 5 ppm or 5 % reading < 1,000 ppm / 10 % reading > 1,000 ppm
NONitric oxide (low)0 … 300 with **0.1 ppm± 2.0 ppm or 5 % reading

 

Other measured componentsMeasuring RangeResolutionAccuracy
Stack / Flue gas temperature32 … 1,472°F (0 … 800°C) with stainless steel

32 … 2,012°F (0 … 1100°C) with Inconel

1 °F± 4°F … < 392°F / 1 % reading > 392°F

± 4°F … < 392°F / 1 % reading > 392°F

Primary air / Ambient air temperature32 … 212°F    (0 … 100 °C)1°F± 2°F
Differential temperatureUp to 2,012°F (0 … 1100°C)

(with suitable material of sampling tube)

1°F± 4°F … < 392°F / 1 % reading > 392°F

 

Stack draft+/- 40 inH2O (120hPa)1 Pa± 0.02 inH2O or 1% reading
Differential pressure+/- 120 inH2O (120hPa)1 Pa± 0.02 inH2O or 1% reading
Gas flow velocity measurement3 … 100 m/s (using Pitot tube)0.1 m/s

 

Calculated valuesRangeCalculated valuesRange
Carbon dioxide0 … CO2 max.Air Ratio (Lambda)1 … 9.99
Heat losses qA0 … 99.9 %Excess Air0 … 99.9
Efficiency0 … 120 %CO/CO2 ratio0 … 10

 

GENERAL SPECIFICATIONS
Max suction range gas pump60 inH2O (150 hPa)
Typical gas flow16 gal/h (60 l/h)
Internal memory16,000 data sets
Data transmissionvia USB, SD Card or Bluetooth
InterfacesSD card reader, USB, Bluetooth
Display3.5″ TFT color display
Operation temperature41°F …. 113°F (5 … 45°C) max. 95 % RH, none condensing
Storage temperature-4°F ….. 122°F (-20°C … 50°C)
Ambient conditionsnot in aggressive, corrosive or high dust ambience, not for use in hazardous areas
Battery operatedLithium-Ion battery, 10 h operation time
Grid power supply100 – 240 V AC / 50 … 60 Hz 2.0A
Protection classIP 30
Weightapprox. 16.5 lbs.
Dimensions( W x H x D) 16.53 x 10.23 x 7.08 inch
TÜV approvalByRgG 280 acc. 1. BImSchV and EN 50379

Download Brochure US

Download Brochure MEX

TEST